Call a SUB every period milliseconds. period 0 disables the tick.
SETTICK period, handler [, slot]
period - interval in milliseconds (0 disables) handler - SUB name slot - 0 to 3 (default 0)
The period is measured from the moment the handler runs, not from the moment it was due. A late handler therefore pushes every later tick back by the same lateness (drift). For exact timing, compare a “due” time against TIMER in the handler instead of relying on the period alone.
Example:
SETTICK 10, GameTick
Source: docs/help/settick.txt inmmcore. On the computer, typeHELP SETTICK.